Skip to content
Home DELTA Industrial Reverse Osmosis System
Three reverse osmosis Delta units installed on a concrete slab inside an industrial warehouse with each unit consisting of horizontally oriented plastic filtration pipe units stacked within a blue metal frame along with an electrical panel and pipes of various sizes with valve and gauge components

DELTA Reverse Osmosis (RO) Systems

DELTA Reverse Osmosis (RO) Systems provides effective, continuous dissolved solids recovery up to 80%+ in a modular small footprint design.  The DELTA Systems can accommodate a wide range of feed water qualities with either a single or double pass and offer you very consistent permeate quality for increased boiler blow-down and reduced scaling.

Three reverse osmosis Delta units installed on a concrete slab inside an industrial warehouse with each unit consisting of horizontally oriented plastic filtration pipe units stacked within a blue metal frame along with an electrical panel and pipes of various sizes with valve and gauge components

Product Overview

Newterra’s DELTA Reverse Osmosis (RO) Systems provide cutting-edge water purification technology for industrial applications, effectively removing a wide range of contaminants, including dissolved salts, bacteria, and particles. These systems utilize a high-pressure pump to force water through semi-permeable membranes, capturing impurities and allowing only clean water to pass through. Designed for efficiency and reliability, the DELTA RO Systems are capable of handling varying feed water qualities, ensuring consistent output of high-purity water. Their modular design allows for easy scalability to meet increased demand, while advanced monitoring and control features ensure optimal performance and minimize maintenance requirements. Ideal for industries such as pharmaceuticals, food and beverage, and electronics manufacturing, Newterra’s DELTA RO Systems offer a sustainable solution for achieving stringent water quality standards.

Features

  • 300-psig rated fiber-reinforced polymer (FRP) reverse osmosis vessels
  • Spiral-wound high-rejection thin-film polyamide reverse osmosis elements
  • 5-micron nominal stainless-steel body pre-treatment cartridge filter with isolation valves
  • Vertical, multi-stage centrifugal booster pump with stainless steel (SS) wetted parts, VFD starter and manual isolation valves
  • Lug-style pneumatically actuated feed butterfly valve with stainless steel disc & stem, ethylene propylene diene monomer (EPDM) seat, steel body and two-way National Electrical Manufacturers Association (NEMA) 4 Underwriters’ Laboratories (UL) certified 24V solenoid
  • Stainless steel globe valve for reject flow control
  • NSF International (NSF) certified paddlewheel-style flowmeters (on feed and product) with polypropylene body (> 100 psig rated up to 120oF), fluoroelastomer (FKM) O-rings, Titanium pin, polyvinylidene fluoride (PVDF) rotor, UL certified
  • Schedule 80 polyvinyl chloride (PVC) low-pressure piping with 304 SS piping on high-pressure lines
  • Cartridge feed/discharge, RO feed, interstage, reject and product pressure gauges (2.5” dial, stainless case, glycerin filled)
  • Manual sample ports on permeate from each vessel with PVC ball valves
  • Epoxy-coated steel skid frame
  • Conductivity sensor with polybutylene terephthalate (PBT) national pipe tapered threads (NPT) mount, NEMA 4X enclosure, Conformité Européenne (CE) certified
  • Optional Polyethylene tank-based clean-in-place system complete with cleaning pump, electric heater, diaphragm flow control valve and PVC piping

Technical Specifications

ModelGPMGPDM3/DStagesHP# Elements
Per Vessel
Recovery
(no Recycle)
DELTA-100100144,000545225475%
DELTA-150150216,000820230675%
DELTA-200200288,0001,100240675%
DELTA-300300432,0001,600250675%
DELTA-450450659,0002,5002100675%
NOTE: Models shown are maxed flow for stated phosphoric acid-impregnated media (HP).
Other models are available. Based on feed water at 25°C with total dissolved solids (TDS) of 1,500 ppm.

Options Available

  • American Society of Mechanical Engineers (ASME) code stamped vessels
  • Substitution of flowmeters for magnetic-type flowmeters
  • Stainless steel low-pressure piping
  • Substitute high-rejection membranes with low-pressure membranes
  • Feed re-pressurization pump
  • Online potential of hydrogen (pH) and Oxidation-Reduction Potential (ORP) monitors
  • Pre-treatment chemical dosing systems (antiscalant, acid, caustic and sodium bisulfite)
  • Automatic flush with permeate option
  • Seismic zone rated
  • Calcite polishing filter
  • Polyethylene tank-based clean-in-place system complete with cleaning pump, electric heater, diaphragm flow control valve and polyvinyl chloride (PVC) piping

Related Content

Newterra custom reverse osmosis system consists of a fourteen white pipes stacked in four columns consisting of four pipes, three pipes, four pipes, and three pipes when read left to right with a blue enameled steel frame with steel pipes leading to a control box within a water treatment warehouse.

Custom Reverse Osmosis Systems

Custom Reverse Osmosis (RO) Systems provide effective, continuous dissolved solids recovery of up to +80% in a modular and scalable design. These tailored systems can accommodate a wide range of feed water qualities with a single or double pass and differing stage configurations and arrays. You’ll receive a consistent permeate quality for your specific application.